IP Link
®
Device Interface
Communication Sheet
Revision: 2/28/2013
Page 1 of 4
This document provides additional assistance with wiring your Extron IP Link enabled product to your device.
Different components may require a different wiring scheme than those listed below.
For complete operating instructions, refer to the user's manual for the specific Extron IP Link enabled product or
the controlled device manufacturer supplied documentation.
Version History:
Device Specifications:
Device Type: Audio Processor
Manufacturer: ClearOne
Firmware Version: 2.5.0
Model(s): XAP800
Driver
Version
Date
IP Link
Compiler
GC
Version
Notes
7 2/15/2013 1.5.1 3.3.2 Modify feedback parsing.
6 01/10/2013 1.5.1 3.3.2 Updated driver to most current A/V conference standards.
5 11/11/2010 1.4.0 3.0.4 Extron Certified. Tested on XAP800. Added input mute, output
mute, process mute, microphone mute, and line mutes and their
status. Updated driver to current standards.
4 6/14/10 1.4.0 3.0.3 Extron Certified. No functionality changes. Revised comm sheet.
3 06/12/07 1.3.11.1 2.2.1 Extron Certified. tested on XAP800. Added Macro Recall, Bus
Gain, Bus Gain Up/Down
2 04/17/06 1.0.9.3 2.1 Extron Certified, tested on XAP800
1 05/20/05 1.0.9.3 1.6 Extron Certified, tested on XAP800
Driver Notes:
Default Device ID is set to 0.
For MLC62 control, ClearOne Device ID must be set to 0.
This driver includes Volume Optimization.
Flow control must be set to “Off” on the ClearOne XAP800 unit
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - Page 1 of 4

clr1_25_2178_7.pke IP Link® Device Interface Communication Sheet Revision: 2/28/2013 Page 1 of 4 This document provides additional assistance wi

Page 2 - Page 2 of 4

clr1_25_2178_7.pke IP Link® Device Interface Communication Sheet Revision: 2/28/2013 Page 2 of 4 Control Commands & States: Device ID 0 – 7

Page 3 - Page 3 of 4

clr1_25_2178_7.pke IP Link® Device Interface Communication Sheet Revision: 2/28/2013 Page 3 of 4 Status Available: Connection Status Connected

Page 4 - Page 4 of 4

clr1_25_2178_7.pke IP Link® Device Interface Communication Sheet Revision: 2/28/2013 Page 4 of 4 Cable and Adapter Requirements: M/F RS-232 Str