DSPVER DSPVersion
This command reports the version of the DSP code in the INTERACT Pro and AT unit. This command is read
only.
ARGUMENT DETAILS
Name Type Size Values
Value Unsigned Integer 4
0 for Host
1 for Satellite
9 for Telco (Pro only)
Value Unsigned Integer 32 (Sent with a Null in text)
Value Unsigned Integer 32
TEXT FORM DETAILS
COMMAND FORM:DEVICE DSPVER <Value>
DSPVEREX 8i DSP Version
This command reports the version of the DSP code in the INTERACT Pro 8i unit. This command is read
only.
ARGUMENT DETAILS
Name Type Size Values
Value Unsigned Integer 4
0 for Host
1 for Satellite
Value Unsigned Integer 32 (Sent with a Null in text)
Value Unsigned Integer 32
TEXT FORM DETAILS
COMMAND FORM:DEVICE DSPVER <Value>
DTMFLVL DTMFTone Level
This command selects/reports the DTMF tone's level.
ARGUMENT DETAILS
Name Type Size Values
Channel Channel 1 See GroupAndChannels
Group Group 1 17 (R)
Value Signed Float 2
For Interact PRO
-65.00 to 0.00 dB
For Interact AT
-14.00 to 0.00 dB
(Null to query in text)
TEXT FORM DETAILS
COMMAND FORM:DEVICE DTMFLVL<Channel><Value>
DUPDATE Update Notification when downloading
This command reports updates when downloading information to the mixer. If sent to the mixer, it will cancel
a download.